Exceptionally compact, lightweight, and
designed for the way you work, the 504DX series offers advanced DOX™
pulse oximetry and heart rate monitoring, plus the reliability and ease
of use that have put Criticare monitors in a class by themselves.
Ergonomic design and intuitive operations. Unique DOX™ digital SpO2
technology improves performance, even under the most challenging
clinical conditions. Full-featured audible and visual alarms ensure
accurate extended, unattended monitoring. The optional fully-integrated,
internal printer produces high quality hard copies of graphic trends,
tabular trends, and sleep summary reports. In addition, the 504DX series
interfaces with Profox* Oximetry sleep study software.
|
|
|
 |
Pulse Oximetry
Range: 0% to 99%
Resolution:1%
Accuracy: 70% to 99% range: ±2%; 40% to 69% range: ±3%; <40%:
unspecified
Method: Dual wavelength LED
Heart (Pulse) Rate
Range: 20 to 300bpm
Resolution: 1bpm
Accuracy: ±1bpm or ±1%, whichever is greater
Alarms
Physiological/System: Audible; visual (EN475); adjustable volume
Silence: Yes; Temporary (2 min) or Permanent
Parameter/Range/ Default:
- High Saturation: 70% to 98% or Off; Off
- Low Saturation: 30% to 99% or Off; 85%
- High Pulse: 80 to 250bpm or Off; 150bpm
- Low Pulse: 20 to 150bpm or Off; 50bpm
Displays
Type: LED
Parameters: SpO2; pulse rate; pulse bar
Status: Alarm Silence; Sensor; Low Battery; External Power; Neonatal
Mode
Text: Alphanumeric LCD
Languages: Selectable; English, French, German, Italian, Portuguese,
Spanish
Data Storage
Capacity: 24 hr at 4 sec intervals
System Output
Com Port: RS 232-compatible; digital or analog; mini-din
Serial Interfaces: ASCII, text, or CSV; Profox-compatible
Printer
Type: Thermal line printer; optional
Tabular Mode: 5, 15, 30 sec intervals; 1, 2, 3, 5, 10, 15, 30, 60 min
intervals; Off
Graphical Mode:
Resolution: 5, 15, 30 sec; 1, 2 min
Span: 1, 4, 8, 12, 24 hr
Mechanical
Weight: With printer and battery: 3.34 lb; 1.52kg
Size: Base unit: 5.67" (H) x 7" (W) x 4.81" (D); 14.4cm
(H) x 17.8cm (W) x 12.2cm (D)
Power Requirements
Voltage: 60 Hz: 110/120 VAC; 50 Hz: 220/240 VAC
Battery: Sealed lead acid; life: 6 hr, typical; recharge time: 8 hr
Environmental
Operating Temperature: 32º to 113º F; 0º to 45º C
Storage Temperature: 23º to 131º F; -5º to 55º C
Operating Humidity: 15% to 90%, noncondensing
Approved by UL, CSA, CE. Quality systems registered to ISO 9001 and CE
marking per Annex II, Clause 3 of Council Directive No. 93/42/EEC
concerning medical devices by TÜV Product Service GmbH, Munich.
Specifications subject to change without notice.
Manufactured in USA.
|
 |
504DX/P Digital Pulse Oximeter Series Accessories
Reusable Sensors
| Catalog Number |
Description |
| 511-10DN |
Adult Reusable Finger Sensor 10 ft. |
| 511SDN |
Adult Reusable Finger Sensor 3 ft. |
| 940SD |
(Forehead applicator, headband, ear clip, double
sided adhesives, microfoam tape.) |
| 511HP |
Adult 3 ft. Sensor and 10 ft. Patient Cable |
| 940HP |
Multi-Site 3 ft. Sensor and 10 ft. Patient Cable |
Disposable Sensors
| Catalog Number |
Description |
| 570SD |
Adult Disposable Sensors (Box of 25) |
| 571SD |
Pediatric Disposable Sensors (Box of 25) |
| 572SD |
Infant Disposable Sensors (Box of 25) |
| 573SD |
Neonatal Disposable Sensors (Box of 25) |
| 574SD |
Variety Pack Disposable Sensors (Box of 25) (10
ea. Adult, 5 ea. Pediatric, 5 ea. Infant, 5 ea. Neonatal) |
Multi-Site Sensor Accessories
| Catalog Number |
Description |
| 514 |
Ear Clip Attachment |
| 525 |
Double Sided Adhesive Dots (Pkg. of 50) |
| 526 |
Microfoam Tape (4" strips - Pkg. of 14) |
| 920 |
Posey Wraps with Holes (Pkg. of 12) |
Other Accessories
| Catalog Number |
Description |
| 553 |
Printer Paper 60 mm (5 rolls) |
| 518DD |
DB-9 to DB-9 Patient Cable 10 ft. |
|
|
| 931S |
Serial Interface Cable |
| 931A |
Analog Interface Cable |
| 1028 |
Roll Stand with Basket |
| 1049 |
IV Pole Mount |
| 1013 |
Carrying Case |
| 908 |
AC Charger 120V |
| 908U |
AC Charger 220V |
| 80514B001 |
Battery |
|