Criticare 8500 Poet IQ Anesthetic Gas Monitor

  8500 Poet IQ
Anesthetic Gas  Monitor

Vital signs and 5-agent gas analysis technology are a powerful combination. Simple to operate in less time and with greater accuracy.  The combination of the Poet IQ® Gas Monitor with the Poet Plus® 8100 Vital Signs Monitor provides a unique combination of leading edge vital signs technology and anesthesia gas monitoring in a compact modular system.  Inspired and expired CO2, N2O, O2, and five anesthetic agents are automatically identified and quantified by the Poet IQ. The easy use, flexible design, reliable performance and affordable cost make it the ideal monitoring unit for anesthesia applications in hospitals and surgical centers.


Features & Benefits
 
  • State-of-the-art NDIR technology identifies and measures five anesthetic agent gases: Halothane, Isoflurane, Enflurane, Sevoflurane, and Desflurane.

  • Automatic or manual.

  • Breath-by-breath O2, CO2, and N2O monitoring.

  • Gas flow sampled at 100, 150 and 200 ml/min.

  • Mixed agent identification.

  • Measurement accuracy is not affected by alcohol or ketones.

  • Fast warm-up time ensures full accuracy within minutes.

  • No user calibration required; minimal user interaction.

  • Intuitive, easily configured user interface minimizes training and is ideal for multiple users.

  • Bright, real-time display of numerical values and waveforms provides instant notification of changing patient status.

  • Lightweight, portable design provides flexible workspace options.
     

  Technical Specifications


Gas Monitoring

Method: Sidestream; Non-dispersive infrared (NDIR)
Identified Gases: Halothane, Isoflurane, Enflurane, Desflurane, Sevoflurane, CO2, N2O, Oxygen
Output Data: Inspired and end-tidal gas concentrations; continuous real-time gas concentrations; respiratory rate (elapsed time since last breath); agent identification (primary agent and mixed agents); system information (diagnostic status
messages)

Agent Detection

Measurement Range:
Halothane: 0 to 10%
Isoflurane: 0 to 10%
Enflurane: 0 to 10%
Desflurane: 0 to 20%
Sevoflurane: 0 to 10%
CO2: 0 to 12.5%
N2O: 0 to 99%
Oxygen: 0 to 100%

Measurement Accuracy:
Agents: ± (0.1% abs. + 4% reading)
CO2: ± 0.2% abs. or 4% of reading
N2O: ± (1.5% abs. + 4% of reading)
Oxygen: ± 3 vol.% (for 0-90%), ± 4 vol.% (for 91-99
%)


Time to Detect Agent: < 15 seconds @ 200 ml/min
Agent Detection Resolution: 0.1 Volume Percent
Mixed Gas Threshold: 0.2 vol. % +10% of total concentrations


Rise Time:
Agents: 450 msec
CO2: 350 msec
N2O: 400 msec
Oxygen: 600 msec

Respiration Rate:
Range: 1 to 60 breaths/minute
Accuracy: ± 2 bpm or 2% of
reading

 

System Features

System Configuration: Modular design with by-directional communication, via cable, to the Poet Plus 8100 vital signs monitor.

Waveform Output:
Halothane, Isoflurane, Enflurane, Desflurane, Sevoflurane, CO2, N2O, O2
Concentration Units: Vol.%, Torr, kPa, mmHg
Flow Rates: 100 ml/min, 150 ml/min, 200 ml/min
Occlusion Clearing: Automatic

Auto Zeroing: Occurs 30 to 60 minutes
Duration: 3.0 to 7.0 seconds
Manual user calibration not required
Temperature stabilized optical assembly

Alarm Characteristics:
EN 475, Adjustable; with audible and visual indications from the vital signs monitor.
Alarm Levels: High, Medium, Low, Informational

Alarm Modes: Adult/Pediatric/Neonate
High and low limit settings for each mode.

Trends: 24 hours of stored data in vital signs monitor with graphical and tabular trends.

Power Requirements

10 to 28 VDC: 9 watts warm-up, 6 watts operational
Receives power from vital signs monitor.

Mechanical

Weight: 6.5 lbs. (2.95 kg.)
Size: 3.8” (H) x 10.4” (W) x 8.2” (D); 9.65 cm (H) x 26.4 cm (W) x 20.8 cm (D)

 

Environmental

Operating Temperature: 15º to 35º C; 59º to 95º F
Storage Temperature: -5º to 50º C; 23º to 122º F
Operating/ Storage Humidity: 15% to 95%, noncondensing
Altitude: -1,000 to 10,000 ft. (-300m to 3000m)
Type of Protection: Class I Equipment
Degree of Protection: Type CF, Defibrillator-proof
Protection against ingress:
Ordinary


Specifications subject to change without notice.

 
  Catalog & Accessory Information
   

Gas Monitoring Accessories

Sampling Devices

Catalog Number
Description

625N

Sample Lines (Box of 25)

624

Disposable Nasal Cannula (Box of 10)

628

Divided Nasal Cannula (Box of 10)

637

Oral/Nasal Sampling Cannula

616

Endotracheal Adaptor, Straight (Box 10)

617

Endotracheal Adaptor, Elbow (Box of 10)

938F-NC

WaterChek 2+ Water Trap (Box of 30)

644

Replacement O2 Cell

655

Scavenging Kit (Exhaust Line & Adaptor)

Calibration Accessories

Catalog Number
Description

621

Cal Gas Cylinder (5% CO2, Balance N2)

622

Cal Gas Cylinder (10% CO2, Balance N2)

716

Cal Gas Cylinder (95% O2, Balance CO2)

620

Cal Gas Cylinder (100% N2)

623

Hardware Regulator For Cylinder

613

Regulator Tubing

641

Cal Gas Aerosol (5% CO2, Balance N2)

642

Cal Gas Aerosol (10% CO2, Balance N2)

631

Cal Gas Aerosol (1% Isoflurane, 5% O2, 60% N2O, Balance N2)

634

Cal Gas Aerosol (1% Enflurane, 5% CO2, 60% N2O, Balance N2)

635

Cal Gas Aerosol (1% Halothane, 5% CO2, 60% N2O, Balance N2)

1367

Cal Gas Aerosol (1% Sevoflurane, 5% CO2, 60% N2O, Balance N2)

1366

Cal Gas Aerosol (4% Desflurane, 5% CO2, 60% N2O, Balance N2)

Calibration Kits

Catalog Number
Description

612

CO2 only (Non-Anesthetic Agent) 5% CO2 cylinder, 10% CO2 Cylinder, Hardware regulator with tubing, plastic storage case.

715

CO2 and O2 (Non-Anesthetic Agent) 5% CO2 cylinder, 10% CO2 Cylinder, 95% O2 cylinder regulator with tubing, plastic storage case.

1365

Anesthetic Agent Verification Kit (5 Agent) One of each five aerosol agents, ISO, ENF, HAL, SEV, DES as described above, includes plastic regulators with tubing.

909

Power Cord (Domestic US)

910UK

Power Cord (United Kingdom)

910INT

Power Cord (International)

910 Unterm

Power Cord (Unterminated)

603 Japan

Power Cord (Japan)